SAT252-55A Temperature-variable test chamber

For high and low temperature testing of inertial systems, It is suitable for environmental simulation tests of moving specimens in aviation, aerospace, electronics and other industries, Verify the reliability of the specimen in practical application.

关键词:

Category:

key word: SAT252-55A Temperature-variable test chamber

Details

For high and low temperature testing of inertial systems, It is suitable for environmental simulation tests of moving specimens in aviation, aerospace, electronics and other industries, Verify the reliability of the specimen in practical application.

1

Main features :

▪ World-class assembly technology

▪ Energy saving in low temperature zone is more than 30%

▪ Excellent performance

▪ Compact shape ,Mobile convenience

▪ Humanized operation interface, one-click start and stop, no professional training required

▪ Multiple protection

▪ Timely response service

1

Application field:

▪ Aerospace

▪ Electrical and Electronics

▪ Instrumentation

▪ Research Institutes

▪ Ships

Specifications :

Product model

SAT252-55A

Content product (L)

252

Inner box size (mm)

W

600

 

H

700

 

D

600  Split unit size

Outer box size (mm)

W

900

H

1000

D

1100

Temperature range (℃)

-70~150℃

Temperature fluctuation (℃)

±0.5℃

Temperature uniformity (℃)

≤2.0℃

Temperature deviation (℃)

±2.0℃

Rising and cooling rate

+85℃~-55℃≥3℃/min(Load 40kg aluminum, average throughout the process)

linearly adjustable

Linear 0.5~ 1 ℃ adjustable

Cooling time

≤28 min(No-load time)

Temperature and humidity control method

BTHC Balanced temperature control and humidity method

Ambient temperature

+5~+35℃

Material

Shell

Double-sided galvanized steel sheet, surface electrostatic spray treatment

Endosome

Matte stainless steel plate  SUS304

Executive Agency

Adiabatic

Rigid polyurethane vinegar foam + glass fiber

Fan

Centrifugal fan

Compressor

French Taikang piston compressor, German blog semi-hermetic compressor

Controller

Display

TFT True color LCD touch screen

Operation mode

Valuation method, program method

Setting method

Chinese and English menu, touch input

Program capacity

120 programs, 99 segments per program, can be set to repeat infinite cycles (maximum 999 cycles per cycle step). Programs can be linked

Set range

Temperature setting range: Adjust according to the maximum working range of the equipment (upper limit + 5°C, lower limit 5°C) Temperature setting range: 0~ 100% RH (equipment humidity)

Display resolution

Temperature: 0.1℃; time 0.1min; humidity 0.1% RH (humidity type only)

 

Product model

SAT252-55A

Controller

Sensor input

PT100(Platinum resistor)

Communication function

(Optional) RS-485 interface, with local and remote communication functions (requires centralized monitoring software, RS-485/RS-232 converter, requires one COM port and one USB port of the PC); up to 16 devices can be connected simultaneously, and the cumulative cable length is up to 800M

PC software usage environment: IBM PC compatible machine, CPU above PII, memory above 128M, Simplified Chinese windows2000 or Simplified Chinese operating system

Control method

Anti-integral saturation PID

Curve observation

With SRAM with battery protection, it can maintain the set value, measured value and sampling time of the device, and can swipe on the touch screen to observe historical data.

Data collection

 

1. Curve display output - directly save the curve display interface or any interface required by the customer as a BMP file and transfer it to the U disk.

2. USB function - with a large-capacity U disk, a controller automatically saves the experimental data according to the sampling period. Users can insert the U disk at any time to check the data export and generate CSV format files (non-graph). The sampling period is 8 seconds, 30 seconds, and 1 minute. The maximum storage time is 46 days, 173 days, and 347 days, respectively.

3. Connect the printer (optional) - connect to the industrial micro printer. Set the number of prints according to the time to print the verification date, measured temperature and test humidity.

4. Connect the PC (optional) - Connect the centralized monitoring software to record the test data. The curve is automatically displayed in the PC and directly output to the printer. The PC can be used as a remote end point to realize remote monitoring.

Subsidiary function

Fault alarm and cause, processing prompt function; power failure protection function; upper and lower limit temperature protection function; timing light machine function; user operation authority function;

Water supply

Water supply method

Water pump

Circulating water flow

2

power supply

AC380(1±10%)V(50±0.5)Hz 

Three-phase four-wire + protective ground wire

Maximum current (A)

1.3

Power (KW)

6.5

Weight (kg)

300

Standard configuration

One electric heating film glass observation window, one left and right test hole (φ 50), 2 sets of sample holders, 1 lighting lamp, 4 casters, and 1 sample power control terminal

safety standard

Leakage circuit breaker, fan overheating protection, compressor overpressure, overheating protection, phase sequence protection, heat fuse wire, dry burning overheating protection, etc.

Inquiry